1、墻板和天花吊頂板在組裝之前應對板材的材質、品類、規格尺寸、特性以及夾心板的芯材進行檢查、核實是否能滿足設計要求;必要時對取樣進行功能測試(阻燃性、安全性不含毒性、抗壓強度等特性)。
1. Before the assembly of wallboard and ceiling board, the material, category, specification, size and characteristics of the board and the core material of sandwich board shall be checked to verify whether they can meet the design requirements; If necessary, the sampling shall be subject to functional test (flame retardancy and safety, excluding toxicity, compressive strength and other characteristics).
2、墻板和天花吊頂板在組裝之前應對天花吊頂上、夾墻內已施工完成后的隱藏工程進行工程驗收,并達到合格要求,方能進行墻板和天花吊頂板的施工。
2. Before the assembly of wallboard and ceiling board, the concealed works on the ceiling and in the sandwich wall after construction shall be accepted and meet the qualified requirements before the construction of wallboard and ceiling board can be carried out.
3、天花吊頂板和墻板在組裝時空氣過濾器送風口、燈具、感溫感煙元件、揚聲器以及門、窗、管道的穿板處,其洞口周圍要整齊、嚴密、清潔、不產塵,其縫隙應用不燃材質封堵;檢查口的周邊也要很好的封口。
3. At the air filter air supply outlet, lamps, temperature and smoke sensing elements, loudspeakers, doors, windows and pipe penetrations during the assembly of ceiling panels and wall panels, the openings shall be neat, tight, clean and free of dust, and the gaps shall be sealed with non combustible materials; The periphery of the inspection port shall also be well sealed.
4、天花吊頂板和墻板的拼縫應均勻一致,拼縫的間隙誤差應不得超過0.5毫米,拼縫應用密封膠均勻封口,封口處應整齊、光滑、略低于板面。
4. The joint of ceiling plate and wall plate shall be uniform, and the gap error of joint shall not exceed 0.5mm. The joint shall be evenly sealed with sealant, and the sealing part shall be neat, smooth and slightly lower than the plate surface.
5、墻板組裝應垂直,天花吊頂板組裝應水平,板面整齊,部位準確,墻與地、墻與頂、墻與墻、頂與頂相互之間的相接處應有合理的結構設計,保證封口,防止開裂,拐角處宜為圓角。
5. The wallboard assembly shall be vertical, the ceiling board assembly shall be horizontal, the board surface shall be neat and the position shall be accurate. The joints between wall and ground, wall and top, wall and wall, top and top shall have reasonable structural design to ensure sealing and prevent cracking. The corners should be rounded.
6、板材組裝的垂直角度≤1.5毫米,表面平面度≤1.5毫米,板與板相互之間,接口處的高低差≤1.0mm。
6. The vertical angle of plate assembly is ≤ 1.5mm, the surface flatness is ≤ 1.5mm, and the height difference between plates and at the interface is ≤ 1.0mm.
7、板材組裝后應進行保護防止碰撞破壞板面。
7. After the plate is assembled, it shall be protected to prevent the plate surface from being damaged by collision.
8、板材表面應整齊、光滑、色澤一致,板材表面的保護膜應完好無損,交工前再撕膜。彩鋼夾芯板隔墻